PACEMAKER FLAMEPROOF THYRISTOR SWITCH TYPE WROT 1400.2T

Zakład Automatyki Przemysłowej A. OZIMIŃSKI

Pacemaker switch type WROT 1400.2T is made in flameproof enclosure type ZAP-BLA1 and it is used for soft start power supply and protection of three driving motors of belt tensioning or scrapers with voltage 3x1000VAC or 3x500VAC. Additionally it can supply 1 belt tensioning engines (reversal work) it has supportive transformer to power supply 3 clearances with voltage 3x230VAC or 3x500VAC with possibility of supporting cramps with voltage 42VAC and tapping with voltage 3x127VAC or 3x230VAC.

Rated voltage:

3x500VAC/3x1000VAC

Rated current:

460A

Load drains with conntected tensioning station (sum of drains 4 ≤ 90A):

Sum of drains 1 i 2 i 3 ≤ 360A

Load drains without tensioning station (drain 4 = 0A):

Sum of drains 1 i 2 i 3 ≤ 450A

Max load of a single drain:

400A

Sum of drains releasers:

1000V~ ≤ 1,75A

Outflows to power releasers:

3x230VAC lub 3x500VAC, 42VAC, 5kVA – 2 outflows

Outflows to Power lighting and/or another receiver

3x127VAC lub 3x230VAC, 5kVA – 2 outflaws

The outflow auxiliary controlled:

- The outflow auxiliary controlled 42VAC, 420VA
- Odpływ pomocniczy kontrolowany 24VAC, 200VA

Overall dimensions:

- length: 1750 cm
- width: 885 cm
- height: 1000 cm
- weight: 1600 kg

explosion proof construction:

I M2 Ex d [ia Ma] I Mb lub I M2 Ex d [ib] I Mb

*Zastrzegamy sobie prawo do zmiany parametrów

- 1 power track
- 2 drains for the conveyor
- 2 outflows for a tension station (reverse operations)
- 2 drains for releasers 3x230V lub 3x500V lub 3x1000V + 42V
- 1 additional outflow 1000VAC,
- 2 outflows for drain 3x127V lub 3x230VAC
- 1 drain voltage auxiliary 42V i 24V
- thyristor module for soft start
- system control module thyristor
- reverse switch
- protection from: overload, short circuit, asymmetry, discontinuities ground wire, decrease the insulation resistance on the drains, engine temperatur es, the temperature of thyristors
- intrinsically safe control circuits
- control releasers
- tensioning control station
- lock the door opening from the main chamber
- ability to work on stiff
- digital ammeters
- voltmeter inlet
- signaled control work
- emergency switch
- visualization (on request)
- cooperation with well-known automation systems
- pre-start signaling
- clearing security without opening the chamber
- local control
- integrated Power supply intrinsically safe

DEPARTMENT HAS A CERTIFIED QUALITY MANAGEMENT SYSTEM ISO 9001: 2009